| Vin | Safety Approvals Input Voltage Range | 100~240Vac | |
| Operate Voltage Range | 90~264Vac | ||
| Fin | Input Frequency | 47~63Hz | |
| Po | Output Power Range | 9w | |
| Vo | Output Voltage Range | 9V | |
| Io | Output Current Range | 1A | |
| IiI | Input Current Low Line | Io=Full load, Vin=100VAC | 0.3A |
| Iih | Input Current High Line | Io=Full load, Vin=240VAC | 0.6A |
| Ir | Inrush Current Low Line | Io=Full load, 25ºC ,Cool start, Vin=115Vac | 15A |
| Inrush Current High Line | Io=Full load, 25ºC ,Cool start, Vin=230Vac | 30A | |
| Eff | Efficiency | Io=Full load,Vin=230Vac | 80~90% |
| REG-i | Line Regulation | Io=Full load | 0.5~2% |
| REG-o | Load Regulation | Vin=230Vac | 4~5% |
| OCP | Over Current Protection | Auto recovery | 120~150% |
| Ttr | Time of Transient Response | Io=Full load to Hakf Load, Vin=100Vac | 4mS Max. |
| Th | Hold-up Time | Io=Full load, Vin=110Vac | 10mS Min. |
| Ts | Start Up Time | Io=Full load, Vin=100Vac | 3S Max. |
| Vp-p | Ripple & Noise Peak to Peak | Io=Full load, Vin=90Vac | 1% Max. |
| Ilk | Safety Ground Leakage Current | Vin=240Vac/60Hz | 0.75A Max. |
| TC | Temperature Coefficinet | All output | '+/-0.04%/ºC |
| Pno | No-Load Power Consumption | No load, Vin=230Vac | 0.5W |
| Vps | Dielectric Withstanding Voltage | Primary to secondary | 3750Vac Min./3S |
| Ris | Isolation Resistance | Test Voltage=500Vdc | 50MΩ |
| Environmental: | |||
| To | Operating Temperature | '-29~45.5ºC | |
| Ts | Storage Temperature | '-40~70% | |
| Ho | Operating Humidity | 20~90% | |
| Hr | Storage Humidity | 20~90% | |
| MTBF | Operating Temperature at 25ºC Calculated per MIL-HDBK-217F | 40000 hrs | |